(714) 891-0008 • www.kinginstrumentco.com
When it comes to ow...we’re instrumental.
1
7459 Series
Installation Instructions
Flow Meter liMited warranty
Meters are warranted against defects in materials and workmanship to the original user for a
period of thirteen (13) months from the date of factory shipment, provided the meter is installed,
operated and maintained in accordance with King Instrument Company’s instructions and recom-
mendations.
This warranty does not apply if failure is caused or contributed to by any of the following: im-
proper handling, improper storage, abuse, unsuitable application of the product, lack of reason-
able and necessary maintenance, use exceeding suggested pressure and temperature maximums,
improper packaging for return, or repairs made or attempted to be made by anyone other than
King Instrument Company, Inc.
KING INSTRUMENT COMPANY, INC. MAKES NO WARRANTY AS TO THE FITNESS OF ITS PRODUCTS
FOR SPECIFIC APPLICATIONS.
This warranty is valid for the original end-user only and does not apply to products that have been
damaged or modied. This warranty is non-transferrable and is limited to replacement or repair.
The liability of King Instrument Company arising out of its supply of the products, or their use, shall
not in any case exceed the cost of correcting defects in the products as set forth above.
THIS WARRANTY IS A LIMITED WARRANTY AND SHALL BE IN LIEU OF ANY OTHER WARRANTIES, EX-
PRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OR MERCHANT-
ABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO OTHER WARRANTIES WHICH
EXIST BEYOND THE DESCRIPTION OR FACE HEREOF.
IN NO EVENT SHALL KING INSTRUMENT COMPANY BE LIABLE FOR LOSS OF PROFITS, INDIRECT,
CONSEQUENTIAL OR INCIDENTAL DAMAGES.
Products should be returned, prepaid, to King Instrument Company, Inc. with proof of purchase.
Call factory for Return Merchandise Authorization (RMA) number and return instructions.
this is iMportant inForMation.
read it careFully beFore beginning work.
1) Inspect meter for damage that may have occurred during shipping.
Report any damage to the container to the freight carrier immediately.
2) Make sure your pressure, temperature, uid and other requirements
are compatible with the meter (including o-rings.)
3) Select a suitable location for installation to prevent excess stress on
the meter which may result from:
a) Misaligned pipe.
b) The weight of related plumbing.
c) Water Hammer which is most likely to occur when ow is
suddenly stopped as with quick closing solenoid operated
valves. (If necessary, a surge chamber should be installed. This
will also be useful in pressure start-up situations.)
d) Thermal expansion of liquid in a stagnated or valve isolated
system.
e) Instantaneous pressurization which will stress the meter and
could result in tube failure.
note: In closed thermal transfer or cooling systems, install the meter
in the cool side of the line to minimize meter expansion and contrac-
tion and possible uid leaks at the threaded connections.
4) Handle the meter carefully during installation.
a) Use an appropriate amount of teon tape on external pipe
threads before making connections. Do not use paste or stick
type thread sealing products.
b) Over tightening of plastic connections may result in tting
damage.
5) Install the meter vertically with the inlet port at the bottom.
6) Connections: Fittings are fully rotatable by loosening the tting
retainer screws during installation. Make sure tting retainer screws
are tightening after adjustment of tting
7) Meters with stainless steel ttings will support several feet of pipe
as long as signicant vibration or stress resulting from misaligned pipe
are not factors.
8) Meters with plastic ttings must be installed so that ttings are not
made to support any part of the associated plumbing. In addition,
meter frame should be fastened to bulkhead, panel or column.
9) Meters used in gas service should have suitable valves plumbed in
at the inlet and outlet of the meter. These valves should be no more
than 1-1/2 pipe diameters from the meter ports. The valve at the out-
let should be used to create back pressure as required to prevent oat
bounce. It should be set initially and then left alone. The inlet valve
should be used for throttling purposes. Depending on the installation,
valves may not be essential, but they are most useful in many instal-
lations. Remember: To get a correct reading of ow in gas service, it is
necessary to know the pressure right at the outlet of the meter (before
the valve).
Vue de la page 0
1 2 3

Résumé du contenu

Page 1 - 7459 Series

(714) 891-0008 • www.kinginstrumentco.comWhen it comes to ow...we’re instrumental.17459 SeriesInstallation InstructionsFlow Meter liMited warrantyMet

Page 2

(714) 891-0008 • www.kinginstrumentco.comWhen it comes to ow...we’re instrumental.2caution• O-rings should be replaced if meter is disassembled afte

Page 3

(714) 891-0008 • www.kinginstrumentco.comWhen it comes to ow...we’re instrumental.37459 SeriesInstallation InstructionsInstallation Instructions7459

Commentaires sur ces manuels

Pas de commentaire